2. MAINTENANCE
JCY-1900
/
1950
V
DR Service Manual
29
DOC No. 7ZPNA4409
2.4. Fixed Protective Capsule Unit : NDH-338
2.4.1. Exchange of the beacon
1) The removal method
1
Remove the bracket with Beacon from the cap-
sule unit.
1) Remove four inner side hexagon screws and
remove a bracket.
2
Remove Beacon from bracket.
2) The mounting method
Carry out mounting in the reverse order to removal.
* Do not forget attachment of washer.
* Attach Beacon so that the expiration date can be seen.
* Set the expiration date with maintenance software. (Refer to 2.9.2.)