Loading...
3. OPERATION CHECKING ON HARDWARE
JCY-1900
/
1950
V
DR Service Manual
60
DOC No. 7ZPNA4409
3.4.3. Check of expiration date in Replacement Parts
Check expiration date of the Replacement parts. Refer to 2.1.
Touch [Setup][Replacement parts] to call the Replacement Parts screen.
Refer to Instruction Manual for more information.
* If the expiration date is less than one year, an alert occurs.refer to section 4.
* The OPU Displays the operation time.
3.4.4. Changing the password
Touch [Setup][Change password] to call Change password screen. Input current and new password.
Refer to Instruction Manual for more information.
Password is two kinds.
1) User Password
The factory-set password is "0000". The password must be managed by the ship administrator.
2) Master Password
The password is for service engineers. It is fixed to "9998".
* When user have lost a user password
In Change password screen, input the master password “9998”to [Current password].
And input new user password to [New password] and [New password for verify].
Replacement Parts screen