S4-5  Set the time to th gyro alarm 
 
0.5 seconds ..............[OFF] 
5 seconds .................[ON] 
 
S4-6  Set the sensor 
 
Use the gyro.............[OFF] 
Use the NMEA ........[ON] 
S4-7, 8  Set the baud rate 
 
 4800 9600 19200 38400 
S4-7  OFF ON OFF ON 
S4-8 OFF OFF ON ON 
 
S5: Make settings for S5 according to the type of gyro compass.    Refer to the S5 setting table. 
 
S5-1  Make settings according to the type of 
gyro 
compass. 
 
Synchro signal ............................ [OFF] 
Step signal................................... [ON] 
 
S5-2,3 Make settings according t
o
 the gyration ratio. 
 
 360X 180X 90X 36X 
S5-2 OFF ON  OFF ON 
S5-3 OFF  OFF  ON  ON 
 
S5-4  Set the gyration direction. 
 
Normal (clockwise)..................... [OFF] 
Reverse (counterclockwise) ........ [ON] 
 
S5-5  Set the log type. 
 
Pulse signal ................................. [OFF] 
Synchro signal ............................ [ON] 
 
S5-6 Not in use 
 
S5-7,8  Set the log ratio. 
 
Pulse/NM (pulse signal) 
800 400 200 100 
Gyration/NM (synchro signal) 
 
360X 180X 90X 30X 
S5-7 OFF ON OFF ON 
S5-8 OFF OFF ON ON 
 