Speed log switch setting
1. This radar's compatible standard speed logs are the following eight types:
Pu
lse
type: 800 pulses/NM, 400 pulses/NM, 200 pulses/NM, 100 pulses/NM
Synchro type: 360X/NM, 180X/NM, 90X/NM, 30X/NM
Set the S5 GYRO/LOG select switch according to the S5 setting table.
2. Connect the speed log signal input line to TB20
.
To do so, for the pulse type, connect the
line to the PULSE side and, for the synchro type, connect the line to the SYNC side. With
respect to the positive (+) and negative (-) sides, when the pulse type is selected, the negative
(-) side is the ground.
2) Installing the gyro I/F unit
Install the gyro I/F unit in the radar process
unit accordi
ng to the procedures below:
(1) Remove the radar process unit cabinet cover, loosen the screws that mount the terminal board to the
cabinet, a
n
d remove the terminal board from the radar process unit cabinet.
(2) Combine the removed terminal board with the gyro I/F unit.
3-19