4 
3.  Set a port for each sensor. 
 
Settable sensor signals 
 
GPS, DLOG, Alarm, Depth, Temperature, Wind, Current, ROT, RSA 
 
Selectable ports 
 
When the automatic recognition function is used: AUTO 
When ports are specified: NAV1, NAV2, GPS, and NMEA 
 
 
[III] Reception Sentence Setting (RX Sentence) 
 
Set signal sentences to be received from sensors. 
The system is factory-set for using all sentences. 
To receive only specified sentences, select    No Use    for sentences which are not necessary. 
 
 
 Procedures   1.  Open the Serviceman Menu. 
 
2.  Perform the following menu open procedure to open the RX Sentence 
setting menu. 
 
        2. Installation Menu   
  → 5. COM Port Setting   
  → 3. RX Sentence   
 
3.  Select the sentences to be used by the sensors to be set. 
 
Selection value: (Use) or (No Use) can be set for each sentence. 
 
 1. GPS(LL/COG/SOG)   : GGA/RMC/RMA/GNS/GLL/VTG 
 2. GPS(WPT/Time)   : GGA/RMC/RMB/BWC/BWR/ZDA 
 3. Depth   : DPT/DBK/DBT/DBS 
 4. Wind   : MWV/MWD 
 5. Current 
  Data Set Number    : 0-9. Set the number of the sentence to be used by Data Set 
Number.  (Initial value All) 
  Layer A    : 0-
999. Set the number of the sentence to be used with layer A 
by Layer Number.    (Initial value 3) 
  Layer B    : 0-
999. Set the number of the sentence to be used with layer B 
by Layer Number.    (Initial value 4) 
  Layer C    : 0-
999. Set the number of the sentence to be used with layer C 
by Layer Number.    (Initial value 5) 
  6. Autopilot    : APB (default value : Not Use) 
4-10