57
6
8
When removing/installing the motor, unless the motor is
defective, loosen coupling setscrew 8 without loosening
coupling setscrews 6 and remove the motor with the coupling
installed.
When the motor is separated
from the coupling, set the
clearance between the end face
of the motor and that of the
coupling to 0.5 mm when re-
assembling.
For re-assembling the stepping
motor unit, refer to 3-2)
Adjusting the feed timing.
0.5 mm