– 34 –
The procedure is the reverse of "(1) Changing procedure to bottom feed and the adjustment".
Loosen hinge screw
, move needle bar rocking rod
from needle rocking rod xing base
to needle bar
rocking rod arm
, and x it with hinge screw
.
Replace the feed dog, the throat plate and, the presser with the components for needle feed.
Loosen setscrews
and
󱢶
(2 places) in sprocket
󱢵
. Loosen the setscrews in the order of
󱢶
and
. At
this time, remove the setscrew
which is put in screw hole
C
, and put it in screw hole
A
which is located
on the opposite side at 180˚. (Fig. b)
Turn the pulley by 180˚ without turning the hook driving shaft, align the at section of the hook driving shaft
with screw hole
A
in sprocket
󱢵
, and x with setscrews
. It is the standard that screw No. 1
󱢴
in hook
driving shaft rear bearing
󱢳
aligns with the at section of the hook driving shaft. (Fig. a)
Then x screw No. 2
󱢶
which is put in screw hole
B
in sprocket
󱢵
as well.
(2) Changing procedure to needle feed and the adjustment