– 7 –
4-1. Method of lubrication
For this sewing machine, one of two dierent lubricating methods can be selected.
(2) Method of non-circulation type lubrication (when only the clean oil is always used)
To ensure the long service life of the sewing machine, be sure to clean up the aforementioned
lter sections (at four locations) periodically (approximately once three months). When the lter
is clogged, lubrication trouble will occur and break-down will be caused.
In addition, when the oil becomes dirty, replace the oil gathered in the oil tank and the under cov-
er.
Insert inlet port
❶
for circulation into section
❸
of
the feed box cover until it will go no further to put it
into the state as it has been delivered to your plant.
* Drain oil dropped into the under cover by remov-
ing drain screw
❷
.
Filter for
circulation
Urethan lter
Plunger
4. PREPARATION OF THE SEWING MACHINE
Circulation
Lubrication to
hook side
❷
❶
❸
Filter for plunger
Lubrication
Oil tank
Ball oat case
Oil inlet lter
Reux oil
from hook
(1) Method of circulating lubrication (when the oil collected in the under cover is reused)
When inlet port for circulation
❶
comes
in contact with the oil surface, oil is
absorbed without passing the lter. As a
result, break-down will be caused.
If inlet port
❶
for circulation is not insert-
ed into the feed box cover, oil may leak
from inlet port
❶
for circulation or the
quantity of oil in the hook may uctuate.