– 42 –
6-11. Position of the wiper
6-12. Caution when installing the attachments
1) Adjust engraved marker dot
❶
on the machine arm to white marker dot
❷
on the handwheel.
2) Move rod
❸
in the direction of the arrow, and adjust with two clamping screws
❺
so that the clearance
between the top end of needle and wiper
❹
is approximately 2 mm.
Be careful that screw
A
does not protrude in the
rear of the bed slide when xing the attachment to
the bed slide with the screw.
Needle
❸
❺
❹
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power o and ascertaining that the motor is at rest.
2mm
❷
❶
A
When it protrudes as shown in the gure,
the screw interferes with other compo-
nents and break-down will be caused.