Please read these instructions carefully before use.
SAFETY INSTRUCTIONS
Before installation
Do not connect the product to the mains supply before pipes have been routed and the system
interconnected.
The units are heavy and aluminium chips/sharp edges can cause cuts on the hands. Lift with your
legs, not your back. Always wear gloves and eye protection during assembly.
Read all the instructions and assembly instructions before assembly.
Electrical safety
New installation and extensions to existing systems must always be performed by a qualified electrician.
If you have the necessary experience and knowledge, you may replace switches and wall sockets, fit
plugs, extension cords and lamp holders. If not, you should contact an electrician. Improper installation
may result in electric shock or fire.
IMPORTANT!
The system must be connected to an earthed mains supply (230 VAC, 50 Hz, 10 A), with a residual
current device with a maximum tripping current of 30 mA and overvoltage protection.
Never poke your fingers or objects inside the unit when the system is running. Risk of personal
injury and/or damage to property.
Never pour water over the unit. Never cover the unit, partly or fully – risk of overheating.
If the unit stops or shuts down, wait 3 minutes before restarting the unit.
TECHNICAL DATA
Heat output kW 4,4
Refrigerant, quantity kg R410A, 0,9 KG
Power consumption kW 0,8
Fan speed rpm 850
Water pressure drop kPa 10
Noise level dB(A) 55
Water connection
40 mm
Net weight kg 46