    What to do if Julabo Industrial Equipment shows a low level alarm?
    • C
      Chelsea JohnsonAug 12, 2025
      If the Julabo Industrial Equipment displays a low level alarm, it could be due to several reasons. First, ensure that the circulator has enough bath fluid. If it doesn't, switch off the unit, refill the fluid, and then switch it back on. Another potential cause is a tube breakage leading to fluid loss; in this case, replace the tubing and refill the bath liquid. Lastly, the float itself might be defective, possibly from transport damage. If this is the case, the unit needs repair by authorized JULABO service personnel.
  • K
    Karen JohnsonAug 20, 2025
    How to fix excess temperature protector defect on Julabo Industrial Equipment?
    • J
      Jose RodriguezAug 20, 2025
      If your Julabo Industrial Equipment shows 'Excess temperature protector defect', it means that the protection temperature is set lower than the working temperature setpoint. To resolve this, increase the protection temperature to a value higher than your set working temperature.
  • W
    Wesley SmithAug 27, 2025
    What to do if Julabo Industrial Equipment detects a short-circuit during self-test?
    • L
      Lucas TrujilloAug 27, 2025
      If the Julabo Industrial Equipment detects a short-circuit during the self-test after being switched on, it indicates a short-circuit between pin 2 and pin 4 of the control line, or the control line was disconnected during operation. To solve this, reconnect the control line or repair the short-circuit.
  • Y
    Yolanda PalmerSep 4, 2025
    Why does my Julabo Industrial Equipment show a configuration error?
    • C
      Courtney YangSep 4, 2025
      If a 'Configuration Error' appears on your Julabo Industrial Equipment, it means the circulator's configuration doesn't match its current use. You can attempt a one-time, automatic configuration change by pressing the key. If the problem persists, contact JULABO Technical Service or an authorized dealer for assistance.