Summary

Safety Warnings

General Safety Precautions

Provides essential safety instructions and precautions for operating the circulator unit.

Operating Controls and Functional Elements

Operating Controls and Functional Elements

Front Panel Controls and Indicators

Details the power switch, keys, display, and indicator lights on the front panel.

Unpacking and Checking

Description

Product Description and Features

Overview of JULABO circulators, their function, microprocessor technology, and safety features.

Preparations

5.4. Countercooling

Preparations

5.5. Temperature application to external systems

Instructions for connecting the circulator for temperature control in external closed systems (loops).

Temperature application to external, open systems

5.6. Adjusting the pump flow

6. Operating procedures

6.1. Power connection

Instructions for safely connecting the unit to a grounded mains power socket.

6.2. Switching on / Start - Stop

Steps for switching the unit on, performing self-test, and starting/stopping operation.

Operating procedures

6.3. Setting the temperatures

Setting Working Temperature T1

Procedure for setting the primary working temperature (T1) using the control keys.

Setting Working Temperature T2

Procedure for setting the secondary working temperature (T2) using the control keys.

6.4. Warning functions

Setting the High Temperature Limit

Instructions for setting the upper limit for audible temperature warnings.

Setting the Low Temperature Limit

Instructions for setting the lower limit for audible temperature warnings.

6.5. Setting the safety temperature (with shutdown function)

Excess Temperature Protection Setup

Procedure for setting the safety temperature to prevent overheating and shutdown.

7. Troubleshooting guide / Error messages

Troubleshooting Common Errors

Lists common causes and remedies for error messages like E 01, E 05, E 06.

8. Safety recommendations

General Safety Recommendations

Essential safety advice for operating the circulator to prevent damage and injury.

9. ATC - Absolute Temperature Calibration

10. Configuration for counter-cooling

12. Remote control

12.2. Communication with a PC or a superordinated data system

12.3. List of commands

Command Reference List

A comprehensive list of commands for controlling the circulator via PC, with parameters and responses.

12.5. Error messages

Error Message Reference

Detailed explanations of error messages, their causes, and possible solutions.

13. Cleaning the unit

15. Technical specifications

Technical specifications

Related product manuals