EasyManua.ls Logo

Jung FTR231 - Commissioning

Jung FTR231
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fit device in appliance box; terminals must be at the bottom.
Fit the frame, central plate and control knob.
Switch on mains voltage.
7.1 Commissioning
Setting control behaviour
Factory setting: pulse width modulated control (PWM)
This setting can be used with most heating systems without adaptation.
Changing the settings
Press the control knob for longer than 20 seconds.
The LED flashes
green
for PWM control and
green/blue
for 2-point control.
Press the control knob briefly: The control behaviour is changed.
Press the control knob for longer than one second.
The current control behaviour is saved and the setting mode is exited automat-
ically.
After approx. 2 minutes without any operation the menu is exited without sav-
ing.
Setting the temperature limits
The temperature control has a setting range from 5 to 50 °C. The adjustment rings in
the central plate can be used to limit the temperature setting range.
Floor thermostat
7 / 9
82404903 16.09.2022
J0082404903

Related product manuals