103
03.13 EN
4.2 Preparing the truck for operation
Switching on the truck
Requirements
– For checks and operations to be performed
before starting daily operation, see "Checks and
operations to be performed before starting daily
operation" on page 90.
Procedure
• Unlock the Emergency Disconnect switch (83)
to do this
• Press the rocker in (s) and pull it up until you
feel the Emergency Disconnect switch
engaging.
• Insert the key in the key switch (81) and turn it clockwise as far as it will go to the
“I” position.
• Test the brake pedal and parking brake (108 and 95 lit simultaneously).
Truck is operational. The display (103) shows the remaining battery capacity.
Z When you have pulled the EMERGENCY
DISCONNECT and turned the key switch to the right,
the truck carries out a self test for approx. 3-4 seconds
(tests the controllers and motors). During this time the
truck cannot move or lift. If the accelerator or a lift
mechanism lever is applied during this time, an
information message will be displayed.
83
81 103