4.2.5 Displays
4.2.6 Notes on automatic air conditioning operation
Automatic mode:
The set internal temperature is maintained automatically.
Heater mode:
The cab is heated. The air conditioning compressor is switched off.
Cooling mode:
The cab is cooled. The air conditioning compressor is switched on at an external
temperature 10 °C and switched off at an external temperature of 8 °C. Fan output
is controlled automatically.
Defrosting mode:
The cab windows are defrosted. All air jets under the windows must be opened. The
heater is activated. Fat output is at the highest stage.
Fuel preheating (o)
All other functions are deactivated.
CAUTION!
Regular servicing of the air conditioning system is required to ensure it can
work at a consistently high level, see "Servicing and Inspection" on page 199
163 Display of inside or outside temperature
164 Current operating mode
165 Current air supply (Fresh = fresh air, Rec = recirculated air)
166 Current fan output
163 164
165166