Step 6: Perform Initial Software Configuration
This procedure connects the router to the network but does not enable it to forward
traffic. For complete information about configuring the router to forward traffic, including
examples, see the Junos OS configuration guides.
To configure the software:
Enter Configuration Mode on page 18
Configure User Accounts and Passwords on page 18
Configure System Attributes on page 19
Commit the Configuration on page 19
Enter Configuration Mode
1. Verify that the router is powered on.
2. Log in as the “root” user. There is no password.
3. Start the CLI.
root# cli
root@>
4. Enter configuration mode.
cli> configure
[edit]
root@#
Configure User Accounts and Passwords
For information about using an encrypted password or an SSH public key string (DSA or
RSA), see the Junos OS Administration Library for Routing Devices.
1. Add a password to the root administration user account. Enter a clear-text password.
[edit]
root# set system root-authentication plain-text-password
New password: password
Retype new password: password
2. Create a management console user account.
[edit]
root# set system login user user-name authentication plain-text-password
New Password: password
Retype new password: password
3. Set the user account class to super-user.
[edit]
root@# set system login user user-name class super-user
Copyright © 2016, Juniper Networks, Inc.18
MX104 3D Universal Edge Routers Quick Start

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX104 3D and is the answer not in the manual?

Juniper MX104 3D Specifications

General IconGeneral
Product FamilyMX Series
Operating SystemJunos OS
ModelMX104
Throughput80 Gbps
Memory8 GB
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating Humidity5% to 90% noncondensing
Input Voltage100-240 VAC, 50/60 Hz
Power SupplyDual