Step 2: Install the Router
Tools Required to Install the Router in a Rack on page 6
Install the MX104 Router in the Rack on page 6
Tools Required to Install the Router in a Rack
To install the router in a rack, you need the following tools:
Phillips (+) screwdriver, number 2
ESD grounding wrist strap
Install the MX104 Router in the Rack
The router can be installed horizontally in a rack or cabinet.
Two people are required to install the MX104 router. The chassis weighs approximately
32 lb (14.5 kg). To install the chassis (see Figure 3 on page 7):
1. Ensure that the rack is in its permanent location and is secured to the building. Ensure
that the installation site allows adequate clearance for both airflow and maintenance.
2. Position the router in front of the rack or cabinet.
3. Have one person grasp both sides of the router, lift the router, and position it in the
rack, aligning the mounting bracket holes with the threaded holes in the rack rails.
Make sure the chassis is level.
4. Have the second person install a mounting screw into each of the open mounting
holes aligned with the rack, starting from the bottom.
5. Visually inspect the alignment of the router. If the router is installed properly in the
rack, all the mounting screws on one side of the rack should be aligned with the
mounting screws on the opposite side, and the router should be level.
Copyright © 2016, Juniper Networks, Inc.6
MX104 3D Universal Edge Routers Quick Start

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX104 3D and is the answer not in the manual?

Juniper MX104 3D Specifications

General IconGeneral
Product FamilyMX Series
Operating SystemJunos OS
ModelMX104
Throughput80 Gbps
Memory8 GB
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating Humidity5% to 90% noncondensing
Input Voltage100-240 VAC, 50/60 Hz
Power SupplyDual