CAUTION: The maximum torque rating of the grounding screws on the
router is 4.34 lb-in. (0.49 Nm). The grounding screws may be damaged if
excessive torque is applied. Use only a torque-controlled driver to tighten
screws. Use an appropriately sized driver, with a maximum torque capacity
of 5 lb-in. or less. Ensure that the driver is undamaged and properly
calibrated and that you have been trained in its use. You may wish to use
a driver that is designed to prevent overtorque when the preset torque
level is achieved.
9. Dress the grounding cable, and verify that it does not touch or block access to router
components, and that it does not drape where people could trip on it.
Figure 4: Grounding Points on the MX104 Router
2—1— ScrewsGrounding cable lug
9Copyright © 2016, Juniper Networks, Inc.
Connect the Grounding Cable

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX104 3D and is the answer not in the manual?

Juniper MX104 3D Specifications

General IconGeneral
Product FamilyMX Series
Operating SystemJunos OS
ModelMX104
Throughput80 Gbps
Memory8 GB
Operating Temperature32°F to 104°F (0°C to 40°C)
Operating Humidity5% to 90% noncondensing
Input Voltage100-240 VAC, 50/60 Hz
Power SupplyDual