Step 6: Perform Initial Software Configuration
This procedure connects the router to the network but does not enable it to forward
traffic. For complete information about configuring the router to forward traffic, including
examples, see the Junos OS configuration guides.
To configure the software:
Enter Configuration Mode on page 16
Configure User Accounts and Passwords on page 16
Configure System Attributes on page 17
Commit the Configuration on page 17
Enter Configuration Mode
1. Verify that the router is powered on.
2. Log in as the “root” user. There is no password.
3. Start the CLI.
root# cli
root@>
4. Enter configuration mode.
cli> configure
[edit]
root@#
Configure User Accounts and Passwords
For information about using an encrypted password or an SSH public key string (DSA or
RSA), see authentication.
1. Add a password to the root administration user account. Enter a clear-text password.
[edit]
root# set system root-authentication plain-text-password
New password: password
Retype new password: password
2. Create a management console user account.
[edit]
root# set system login user user-name authentication plain-text-password
New Password: password
Retype new password: password
3. Set the user account class to super-user.
[edit]
root@# set system login user user-name class super-user
Copyright © 2015, Juniper Networks, Inc.16
MX5, MX10, MX40, and MX80 3D Universal Edge Router Quick Start

Other manuals for Juniper MX5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX5 and is the answer not in the manual?

Juniper MX5 Specifications

General IconGeneral
ModelMX5
CategoryNetwork Router
Throughput20 Gbps
Operating SystemJunos OS
Product TypeModular Router
Switching Capacity80 Gbps
MPLSYes
IPv6 SupportYes
Power SupplyAC or DC
Routing ProtocolsBGP, OSPF, IS-IS, RIP
Operating Temperature0°C to 40°C
Memory4 GB
RedundancyPower supply redundancy
Storage8 GB

Related product manuals