5.1. Starting-up of the Julia
• Check oil level of vacuum pump and gear box.
Check that all protection and safety devices have been correctly
installed.
• Check that the vacuum and pressure lines are not obstructed.
Before starting the pumps check that Julia intake is counter
clockwise. A wrong intake direction can seriously damage the vacuum
pump.
Warning: Julia intake is counter clockwise. A
wrong intake direction can seriously damage the
equipment.
Check speed when loaded and functioning: absence of vibrations
or irregular noises.
5.2. Methods of use
Adjust capacity by acting upon rotation: do not use the safety
valve to discharge excess capacity.
Do not exceed the suggested working pressure and maximum
speed. Excessive power consumption may cause fast wear out of
components or breakdowns.
• Centrifugal pump:
- Suitable for fluids containing vegetable fibres. Avoid the suction
of solids in order to prevent the impeller from being damaged;
- Not self-priming. Avoid dry operation: possible damage the
mechanical seal. Food under the head or bring the liquid level to
the height of the suction mouth before starting.
High pressure pump for clean water only. Follow the performance
limits mentioned in this manual in order to avoid damages to the
gearbox.
• Gear movement: verify that the gears are in correct position before
running the gearbox to avoid damages to gears. The gear positioning
must be done when the machine still and not working.
Manual lever or pneumatic cylinder must reach the end of stroke.
Feed pneumatic circuit before starting up the Julia group.
Install magnetic end of strokes on pneumatic cylinders in order to
verify the position more precisely.
5.3. Alternate and combined working
Julia 3000 - 5000
• Julia 3000 and 5000 are equipped with one lever only.
• Shifting the central gear, allows the alternate intake of vacuum pump or centrifugal pump.
• Special execution with wider gear: allows the combined operation of centrifugal and vacuum pumps, or the vacuum pump sole operation.
• Fig 5.1 illustrates the gears positions on Julia 3000-5000.
Fig. 5.1
5
.
Start up
E
XTENDED VERSION PINION
S
TANDARD VERSION
O
NLY CENTRIFUGAL PUMP
O
NLY VACUUM PUMP
C
OMBINED VACUUM PUMP AND
CENTRIFUGAL PUMP