MAX. SPEED – OPERATING SPEED (RPM)
P
2
(bar ABS)
T
2
(°C)
T
2
- T
1
(°C)
PN155 – PN155R
M - 540
PN155 – PN155R
M - 1000
PN155 D / PN155R D
PN155 HDR / PN155R HDR
Max Max Max
540 - 470 1000 - 900 1150 - 1000 2 * 150°C 130
P
1
: absolute pressure during suction T
1
: temperature during suction
P
2
: absolute pressure during delivery T
2
: temperature during delivery
NOTE. * Belt drive only for PN155 D and PN155R D: P
2
= 1,5 abs bars.
Air flow (free air
condition)
l/min 15200
Vacuum at continuous
duty
PN155
60 %
Air flow at 60% vac. l/min 13500
PN155 R
70 %
Max. vacuum % 93 Oil consumption g/h 250
Power required at max.
vacuum
kW 19 Sound pressure level ** dB (A) 79
Power required at 2 abs
bars pressure
kW 23 Weight kg 220
**: only when decompressor at max. speed, 60% vacuum rate, 7 m distance in open field.
Performances referred to decompressor operating at max. speed.
REFERENCE CONDITIONS
:
Conveyed gas: air Functioning in free air.
Reference abs. pressure: 1.013 mbar Reference temperature: 20°C
Vacuum functioning: free outlet Pressure functioning: free inlet
CAREFULLY OBSERVE TH
E FOLLOWING RULES
When transporting the pump, use proper slinging. Store the pump in stable places.
Installation and maintenance must be operated only by qualified personnel wearing the proper clothes
and the necessary tools as well as protection devices.
Before each maintenance operation:
Stop the pump and restore the atmospheric pres
sure.
Disengage the drive system.
Only operate after the pump has cooled down.
When the pump is running, some parts may reach very high temperatures (above 100°C). Use all
necessary precautions to avoid contact.
Operators working nearby must avoid prolonged exposure to the noise emitted by the aspirator, if not
equipped with the proper ear-protection devices.
Avoid accidental suction of solids: solids may be projected at high speed through the exhaust manifold
and cause injure
s.
7. SAFETY AND ACCIDENTS PREVENTION
6. PERFORMANCES
5. USAGE LIMITATIONS