MAX. SPEED – OPERATING SPEED (RPM)
P
2
(bar ABS)
T
2
(°C)
T
2
- T
1
(°C)
PN155 – PN155R
M - 540
PN155 – PN155R
M - 1000
PN155 D / PN155R D
PN155 HDR / PN155R HDR
Max Max Max
540 - 470 1000 - 900 1150 - 1000 2 * 150°C 130
P
1
: absolute pressure during suction T
1
: temperature during suction
P
2
: absolute pressure during delivery T
2
: temperature during delivery
NOTE. * Belt drive only for PN155 D and PN155R D: P
2
= 1,5 abs bars.
Air flow (free air
condition)
l/min 15200
Vacuum at continuous
duty
PN155
60 %
Air flow at 60% vac. l/min 13500
PN155 R
70 %
Max. vacuum % 93 Oil consumption g/h 250
Power required at max.
vacuum
kW 19 Sound pressure level ** dB (A) 79
Power required at 2 abs
bars pressure
kW 23 Weight kg 220
**: only when decompressor at max. speed, 60% vacuum rate, 7 m distance in open field.
Performances referred to decompressor operating at max. speed.
REFERENCE CONDITIONS
:
Conveyed gas: air Functioning in free air.
Reference abs. pressure: 1.013 mbar Reference temperature: 20°C
Vacuum functioning: free outlet Pressure functioning: free inlet
CAREFULLY OBSERVE TH
E FOLLOWING RULES
• When transporting the pump, use proper slinging. Store the pump in stable places.
• Installation and maintenance must be operated only by qualified personnel wearing the proper clothes
and the necessary tools as well as protection devices.
• Before each maintenance operation:
• Stop the pump and restore the atmospheric pres
sure.
• Disengage the drive system.
• Only operate after the pump has cooled down.
• When the pump is running, some parts may reach very high temperatures (above 100°C). Use all
necessary precautions to avoid contact.
•
Operators working nearby must avoid prolonged exposure to the noise emitted by the aspirator, if not
equipped with the proper ear-protection devices.
• Avoid accidental suction of solids: solids may be projected at high speed through the exhaust manifold
and cause injure
s.
7. SAFETY AND ACCIDENTS PREVENTION
6. PERFORMANCES
5. USAGE LIMITATIONS