V-21E3
22
Item
Measuring
instrument
Test point Ad justment part Description
5. COLOUR [Method of adjustm ent using measuring instrument]
PAL COLOUR
1. Input a PA L f ull field colou r bar signal (75% wh it e).
2. En ter th e SERVICE MENU.
3. Select 2. V/C f rom SERVICE ME NU.
4. Select 5. COLOUR with the MENU ▼/▲ key.
5. Set the initial setting value of PAL COLOUR with the MENU
- / + key.
6. Con nect th e osc illosc ope be tween TP -47G /R a nd TP-E (
#
).
7. Ad just P AL COL OUR to bring th e valu e o f (A) in the illustration
to + 12V (W-G). ( Volt age valu e b et we en (W) and (G))
SECAM COLOUR
1. Input a SECAM full field colour bar signal (75% white).
2. Set the initial settin
value of SECAM COLOUR with the MENU
- / + key.
3. Ad just SE CAM CO LOUR to b ring th e valu e of
(A)
in the
illustration t o +8V(W-G). (Voltage value between (W) an d ( G ))
NTSC 3.58 COLOUR
1. Input a NTSC 3. 58 full fie ld colo ur b ar sign al (75 % white) .
2. Set the initial setting value of NTSC 3.58 COLOUR with the
MENU - / + key.
3. Ad just NTSC 3.5 8 COLOUR to bring t he valu e of (A) in th e
illustration t o + 11V