6
Precautions Prior to Use of Calibration
Calibrated result might be different from the factory default data, depending on the operating environment.
During calibration, set the PC to the administrator mode, and disable the screen mode and energy-saving mode of
the PC.
After turning on the power of the projector, set to the Picture Mode for performing calibration. Start calibration after
waiting for about 30 minutes.
Make sure the brightness of the ambient light in the room is the same as that of the operating environment where the
projector is used.
Do not cast a strong ambient light directly on the screen.
Set the “ECO Mode” of the projector to “Off” when the calibration software is
running.
Do not use the remote control and the operation panel when the calibration software is running.
Do not set to the HIDE mode when the calibration software is running.
The calibration does not work when displaying 3D image.
Calibration does not work when Picture Mode has been set to Frame Adapt HDR. Set to another Picture Mode.
Calibration does not work when Color Profile has been set to Off. Set to another Color Profile before performing the
calibration.
Calibration does not work when Lens Aperture has been set to “Auto 1” or “Auto 2”. Set the lens aperture to “Manual”
before performing the calibration.
If an error message is prompted while using the calibration software, close the application and restart the projector.
Wait at least 5 minutes before restarting.
If the application is ended due to the error message while backup, importing or exporting is in progress, restart the
PC, and perform the operations again.
* Upon saving the data after performing calibration, a backup file will be saved automatically to the folder selected in
“Setting”. All data of the projector set prior to this process will be overwritten.
Calibration