1-14
UX-P3
Main adjustment
Measurement Instruments Required for
     Adjustment
 
  1. Low frequency oscillator
 This oscillator should have a capacity to output
    0dBs to 600   at an oscillation frequency of
    50Hz-20kHz.
  2. Attenuator impedance : 600 
  3. Electronic voltmeter
  4. Distortion meter
  5. Frequency counter
  6. Wow & flutter meter
  7. Test tape
 VTT703L : Head azimuth
 VT712 : Tape speed and running unevenness
                   (3kHz)
 VT724 : Reference level (1kHz)
   8. Blank tape
 TYPE 
: AC-225
 TYPE 
: AC-514
  9. Torque gauge : For play and back tension
      FWD(TW2111A), REV(TW2121a) and
      FF/REW(TW2231A)
10. Test disc: CTS-1000
Radio Input signal
      AM frequency --------------------------------------- 400Hz
      AM modulation ---------------------------------------- 30%
   FM frequency --------------------------------------- 400Hz
      FM frequency deviation ------------------------ 22.5kHz
Tuner section
      B/E/EN version
        FM Band cover:  87.5 108MHz
        MW Band cover: 522 1,629kHz
        LW Band cover:  144
288kHz
      EE version
        FM Band cover:  65 74MHz, 87.5 108MHz
        MW Band cover: 522 1,629kHz
        LW Band cover:  144 288kHz
      UB/UF/US/UX/U version 
        FM Band cover:  87.5 108MHz
        MW Band cover: 531
1,602kHz, 530 1,710kHz
        SW Band cover: SW1 2.3 6.995MHz
                                 : SW2 7 21.85MHz
 Voltage applied to tuner                       +B : DC5.7V
 VT : DC 12V
      Reference measurement 
        output                                       26.1mV(0.28V)/3
      Input positions             AM : Standard loop antenna
                                      FM : TP1 (hot) and TP2 (GND) 
Standard measurement position of volume
      Function switch                                            to Tape
      Beat cut switch                                               to Cut
      Super Bass/Active hyper Bass                      to OFF
      Bass Treble                                                to Center
      Adjustment of main volume to reference output  
 VOL : 28
Precautions for measurement
1. Apply 30pF and 33k
to the IF sweeper output
    side and 0.082 F and 100k in series to the 
    sweeper input side.
2. The IF sweeper output level should be made as 
    low as possible within the adjustable range.
3. Since the IF sweeper is a fixed device, there is no
    need to adjust this sweeper.
4. Since a ceramic oscillator is used, there is no need
    to perform any MIX adjustment.
5. Since a fixed coil is used, there is no need to adjust
    the FM tracking.
6. The input and output earth systems are separated. 
    In case of simultaneously measuring the voltage in
    both of the input and output systems with an 
    electronic voltmeter for two channels, therefore, the
    earth should be connected particularly carefully.
7. In the case of BTL connection amp., the minus
    terminal of speaker is not for earthing. Therefore, be
    sure not to connect any other earth terminal to this
    terminal. This system is of an BTL system.
8. For connecting a dummy resistor when measuring
    the output, use the wire with a greater code size.
9. Whenever any mixed tape is used, use the band
    pass filter (DV-12).
Measurement conditions
 
  Power supply voltage 
                        : AC230V (50Hz)----B/E/EE/EN 
                        : AC110/127V/230V(50/60Hz)
                        : UB/UF/US/UX/U
  Reference output : Speaker : 0.775V/4
                                               : Headphone : 0.077V/32
  Reference frequency and
     input level ------------------------------ 1kHz, AUX : -8dBs
     MIX MIC: -54dBs (UB/UF/US/UX/U)
     Input for confirming recording and playback
             characteristics ------------------------- AUX : -28dBs
     Measurement output terminal ------- at Speaker J3002
 
 Load resistance --------------------------- 4