1-30 (No.MB262)
SECTION 4
ADJUSTMENT
4.1 Jigs and test instruments
Remote controller
4.2 Adjustment and check method
4.2.1 Initialize all data to the factory setting
4.2.2 Confirmation of the system micro computer
4.2.3 FL all lighting-up check
4.2.4 Fan motor ON/OFF check
Initialize is complete.
Pressing the [STOP] , [SLEEP] and
[STANDBY/ON] together at Power
ON condition.
FL indication
COLD
Pressing the [STOP] , [SLEEP] and
[STANDBY/ON] together at Power
ON condition.
Setup is complete.
FL indication
08 02 E
or
09 00 E
Pressing the [STOP] , [SLEEP] and
[STANDBY/ON] together at Power
ON condition.
Setup is complete.
FL indication
All of the FL displays light up.
Pressing the [STOP] , [SLEEP] and
[STANDBY/ON] together at Power
ON condition.
Setup is complete.
Fan motor is rotating.