Questions and Answers

  • C
    Carrie OrrAug 17, 2025
    Why Kaco blueplanet 110 TL3 Inverter doesn't feed maximum power into the grid despite high radiation?
    • T
      Travis SullivanAug 18, 2025
      If your Kaco inverter isn't feeding maximum power into the grid despite high radiation, it could be due to particular ambient conditions. Ensure sufficient cooling of the unit. Also, remove any foreign bodies present on the device and clean the cooling fins.
  • J
    jacksonchristineAug 20, 2025
    What to do if the grid fuse trips with Kaco blueplanet 110 TL3?
    • T
      Terri PerezAug 20, 2025
      If the grid fuse trips when using your Kaco Inverter, it may be because the grid fuse capacity is too low. Select a backup fuse with a capacity somewhat higher than the device’s maximum feed-in current. If this doesn't resolve the issue, there may be hardware damage, in which case you should contact KACO Service to test the hardware.
  • A
    Andrew HudsonAug 23, 2025
    How to troubleshoot Kaco Inverter when the LEDs do not light up?
    • W
      William BradyAug 23, 2025
      If the LEDs on your Kaco Inverter do not light up, it could be due to the grid voltage not being available. Check whether the DC and AC voltages are within the permitted limits. If the issue persists, notify KACO Service.
  • A
    Andrew SmithAug 25, 2025
    What to do if Kaco Inverter stops feeding into the grid shortly after being switched on?
    • S
      Steven LittleAug 26, 2025
      If your Kaco Inverter stops feeding into the grid shortly after being switched on, even with sunlight present, the cause may be defective circuit-breakers in the device. Ensure that there is sufficient PV generator power. Another potential cause is a defective grid separation relay, which should be replaced by KACO Service. If neither of these solutions work, notify KACO Service.
  • K
    Kelli MirandaAug 27, 2025
    Why is Kaco blueplanet 110 TL3 Inverter active but not connected to the grid?
    • T
      Tiffany ThompsonAug 27, 2025
      If your Kaco Inverter is active but not connected to the grid, it might be due to a grid-feed interruption caused by a grid fault. Change the grid parameters within the permitted operating limits.
  • R
    Ruth SmithAug 30, 2025
    What causes an impossible daily peak value on Kaco blueplanet 110 TL3 Inverter display?
    • J
      Janice RobertsAug 30, 2025
      If your Kaco Inverter displays an impossible daily peak value, it is likely due to faults in the grid. To reset the value immediately, switch the device off by disconnecting it from the grid and switching off the DC, then switch it back on.
  • J
    Joshua JenkinsSep 2, 2025
    What does 'Fault in fan 2' mean on my Kaco blueplanet 110 TL3 Inverter?
    • K
      Kevin PorterSep 2, 2025
      If your Kaco Inverter displays 'Fault in fan 2', the fan is malfunctioning. Notify KACO Service! With a defective fan, the power is reduced to 50% to avoid the device being destroyed.
  • M
    Matthew FullerSep 4, 2025
    What does 'Fault in fan 3' mean on my Kaco blueplanet 110 TL3?
    • J
      Jeffrey ReevesSep 4, 2025
      If your Kaco Inverter displays 'Fault in fan 3', the fan is malfunctioning. Notify KACO Service! With a defective fan, the power is reduced to 50% to avoid the device being destroyed.
  • A
    Alejandro SuttonSep 7, 2025
    What to do if there is a fault in fan 1 of Kaco blueplanet 110 TL3 Inverter?
    • S
      shannon41Sep 7, 2025
      If there is a fault in fan 1 of your Kaco Inverter, it means that the fan is malfunctioning. Replace defective fan.
  • F
    franksaraSep 9, 2025
    Why don't daily yields correspond to the yields on the feed-in meter of Kaco blueplanet 110 TL3?
    • G
      Gary YoungSep 9, 2025
      If the daily yields on your Kaco Inverter do not correspond to the yields on the feed-in meter, it is due to tolerances of the measuring elements in the device. No action is required.