EasyManua.ls Logo

Kaisai KHC-08RY3 - User Manual

Default Icon
176 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTRUKCJA INSTALACYJNA
INSTALATION MANUAL
POMPA CIEPŁA MONO
MONO TYPE HEAT PUMP
PL
EN

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kaisai KHC-08RY3 and is the answer not in the manual?

Summary

1 Safety Precautions

Electrical and Installation Safety

Electrical Safety Precautions

Details crucial safety measures for electrical connections and handling live parts.

Packaging and Unit Handling Safety

Covers safe handling of packaging materials and unit placement to prevent hazards.

Grounding and Electrical Installation Requirements

Specifies requirements for proper grounding and electrical installation to prevent shocks.

Installation Site and System Safety

Electrical Wiring and Grounding Regulations

Details national wiring regulations, RCD requirements, and site safety checks.

5 Refrigerant Information

6 Installation Site Selection

Site Requirements for Proper Operation

Specifies conditions for selecting an installation site, including ventilation, noise, and space.

Installation Environment Guidance

Installation in Cold Climates

Provides guidance on selecting a location and installing the unit in cold climate conditions to prevent freezing.

Installation in Hot Climates

Advises on installing the unit in hot climates to avoid direct sunlight and ensure accurate temperature measurement.

7 Installation Precautions

Foundation and Installation Requirements

Specifies the need for a strong, level ground and the use of foundation bolts for secure unit installation.

8.3 Cascade System Configuration

9.3 Electronic Control Box

Hydraulic Module Control Board Connections

Maps out the terminals and their functions on the main control board of the hydraulic module.

Main Control Board (PCB B) Connections

Shows the terminal layout and connections for the main control board of the heat pump system.

Main Control Board (PCB B) for 3-Phase Units

Details the terminal layout and connections for the main control board of the heat pump system in 3-phase units.

9.3.4 Backup Heater Control Parts

9.4 Water Piping and Connections

Water Circuit Freeze Protection

Describes the unit's freeze protection functions and the need for insulation on field piping.

9.5 Filling the Water System

9.6 Water Piping Insulation

9.7 Field Wiring Guidelines

Electrical Wiring Work Precautions

Details safety precautions for electrical wiring, including cable fixing, grounding, and GFCI installation.

Field Wiring Overview Diagram

Provides a diagram showing the general field wiring connections between different system components.

Power Supply Wiring Precautions

Covers precautions for connecting the power supply, including terminal types, screw tightening, and wire fixing.

Safety Device Requirements for Wiring

Specifies requirements for wire diameter, voltage variation, and circuit breaker selection for safety.

Cascade System Electrical Control Wiring (1-Phase)

Shows the electrical control wiring diagram for a 1-phase cascade system setup.

Cascade System Electrical Control Wiring (3-Phase)

Illustrates the electrical control wiring diagram for a 3-phase cascade system setup.

9.7.6 Component Connections

10 Start-Up and Configuration

DIP Switch Settings Overview

Explains the location and function of DIP switches S1, S2, and S4 for unit configuration.

Function Settings via DIP Switches

Details specific settings that can be configured using DIP switches for various operational modes.

10.3 Pre-Operation Checks

10.5 Field Settings and User Interface

Navigating and Adjusting Field Settings

Provides instructions on navigating the menu structure and adjusting various field settings.

10.5.10 Factory Settings Restore

10.5.11 Test Run Operations

10.5.18 Parameter Settings Reference

11 Test Run and Final Checks

Post-Installation Final Checks

Lists essential checks to perform after installation but before unit power-up, including wiring and component integrity.

13 Troubleshooting Guide

General Troubleshooting Guidelines

Offers general advice for troubleshooting, emphasizing visual inspection and safety when dealing with activated safety devices.

Common Unit Symptoms and Causes

Lists common symptoms like incorrect temperature or low water flow and suggests corrective actions.

13.3 Operation Parameter Review

13.4 Error Codes and Fault Diagnosis

Sensor Faults and Communication Errors

Details error codes related to sensor failures (solar, buffer tank, water temp) and communication faults.

Communication, Water Flow, and Freeze Protection Errors

Covers errors related to communication, water flow protection, and anti-freeze mode issues.

15 Service Information and Safety

Kaisai KHC-08RY3 Specifications

General IconGeneral
BrandKaisai
ModelKHC-08RY3
CategoryHeat Pump
LanguageEnglish

Related product manuals