To ensure the reliability of the generator and increase its lifespan, the peak capacities may be slightly limited by
circuit breakers.
The optimum operating conditions are ambient temperature of 17–25 °C, barometric pressure of 0.1 MPa
(760 mm Hg), and relative humidity of 50 60%. Under such ambient conditions, the generator can guarantee
maximum performance in terms of the stated specifications. In case of deviations from the above ambient values, the
performance of the generator can be different.
Please note that in order to preserve the lifespan of the generator, continuous loads should not exceed 80% of the
rated power.
Model KSB 2800C KSB 3500C KSB 6500C KSB 6500CE
Voltage, V 230
Maximum power, kW 2,8 3,0 5,5 5,5
Rated power, kW 2,5 2,8 5,0 5,0
Frequency, Hz 50
Current max, A 12,17 13,04 23,91 23,91
Outlets 2*16А 2*16А 1*16А, 1*32А 1*16А, 1*32А
Fuel tank capacity, L 12 15 25 25
Voltmeter / LED display Voltmeter
LED display
(voltage frequency
working hours)
Voltmeter
LED display
(voltage frequency
working hours)
Noise level Lpa(7m)/Lwa, dB 71/96 71/96 72/97 72/97
Output 12 V, A 12/8,3
Engine model KSB 220 KSB 230 KSB 440 KSB 440
Engine type Gasoline powered four-stroke
Power output (hp) 7 7 15 15
Crankcase capacity, cm
3
0,6 0,6 1,1 1,1
Engine capacity, cm
3
210 208 420 420
Voltage regulator AVR
Engine start manual manual manual manual / electric
Power factor, cosφ 1
Dimensions (LxWxH), mm 605x440x435 605x445x450 690x525x550 690x525x550
Net weight, kg 36,6 39,2 66,6 70
Protection class IP23M
Max. altitude above sea level, m 1000
Relative humidity <95%
Rated voltage tolerance – max. 5%
konner-sohnen.com | 4