- If the generator is often working at high temperature or at high load, the oil should be replaced every 25 operating
hours.
- If the engine is often running in dusty or other harsh conditions, please clean the air filter every 10 hours.
- If you missed the maintenance time, perform it as soon as possible to save the generator engine.
TECHNICAL MAINTENANCE WORKS
Node Service type
Before starting
First month or
after 20
working hours
Each 3 months
or
after 50
working hrs
Each 6 months
or
after 100
working hrs
Each year or
after
300 working hrs
Motor oil
Checking
level
Changing
Air lter
Checking/ Cleaning
Changing
Sparking
plug
Cleaning
Changing
Fuel tank
Checking
level
Cleaning
Fuel lter
Cleaning
REPLACING OR ADDING MOTOR OIL:REPLACING OR ADDING MOTOR OIL:
Upon oil level decrease it is necessary to add the required quantity in order
to provide the correct generator operation. It is necessary to check the oil levels
according to technical maintanance schedule.
Motor oil has a serious impact on performance
characteristics and is a major attribute, defining its service
life. Use oils designed for four-stroke cycle vehicle engines,
since such oils contain cleaning additives, which comply or
even exceed SE standards according to API classification (or
equivalent).
RECOMMENDED OILS
7
0
00
CC
10W-30, 10W-40
4040303020201010-10-10-20-20
In general, the engine is recommended to run with motor oils of SAE10W-30, SAE10W-40 viscosity level. Motor oils
with other viscosity levels, may be used only if the average air temperature in your region does not exceed the limits
of the temperature range, specified in the table. Oil viscosity according to SAE standards or service category, are
specified on the API capacity sticker.
fill to here