CHECK THE FUEL LEVELCHECK THE FUEL LEVEL
1. Wear protective gloves to avoid getting gasoline on your skin.
2. Unscrew the fuel cap and check the fuel level in the tank.
3. Fill the fuel tank to the fuel filter level.
4. Tighten the fuel cap securely.
CHECK THE OIL LEVELCHECK THE OIL LEVEL
Recommended fuel: Unleaded gasoline.
Fuel tank volume: see specifications table.
Recommended engine oil: SAE 10W-30, SAE 10W-40.
Recommended engine oil grade: API Service SE type or higher.
Motor oil quantity: see specifications table.
1. Wear protective gloves to avoid getting oil on your skin.
2. Unscrew the oil dipstick and wipe it out with a clean cloth.
3. Insert the dipstick without screwing it in.
4. Check the oil level by a mark on the oil dipstick.
5. Add oil if its level is below the mark on the oil dipstick.
6. Tighten the oil dipstick.
Only unleaded gasoline is recommended for the generator. The
use of leaded gasoline will cause severe damage to internal engine
parts.
IMPORTANT!
fill to here
ENGINE STARTENGINE START
If the generator has not been used for a long time, recharge the
battery with a charger (not included).
IMPORTANT!
Before starting the engine make sure that the total power of tools or power consumers corresponds to the
rated power of the generator. Do not exceed the rated power of the generator. Do not connect any devices
before the engine start! In the power supply mode, the generator should operate no longer
than 30 minutes in the range from rated to maximum power.
Before connecting any devices to the generator, make sure that they are in good condition. If the device that was
connected suddenly stopped or failed, immediately disconnect the power using a safety switch, disconnect the device
and check it out.
STARTING TO WORK
5
Standby generators should not run continuously (e.g. by adding
fuel to the tank or connecting a large fuel tank) or longer than
recommended: 4-6 hours for gasoline generators (depending on
load).
ATTENTION – DANGER!
This material is for informational purposes only and does not constitute a manual for installing the equip-
ment or connecting it to the mains, but we strongly recommend that you read the instructions below.
Equipment connection must always be carried out by a certied electrician responsible for the installation
and electrical connection of the equipment according to local laws and regulations. The manufacturer
assumes no liability for improper connection of the equipment or for any material or physical damage that
may result from improper installation, connection or operation of the equipment.
Do not connect two or more devices simultaneously. The start-up
of many devices requires high power. Devices should be connected
in turn according to their power rating. Do not connect any power
consumers within the first 3 minutes after the generator start.
WARNING - DANGER!