DN1726-0811
KT-400
Ethernet Four-Door Controller
Installation Manual

Table of Contents

Questions and Answers

  • B
    Brandon SmithJul 26, 2025
    What to do if Kantech IP Access Controllers need factory default DHCP?
    • J
      jfreemanJul 26, 2025
      When JP2 and JP3 are OFF: all of the Kantech IP Access Controller's memory is set to default values, the internal event buffer is cleared, the controller generates the message 'Controller Factory Default Reset', and the Ethernet port reverts to DHCP configuration, waiting for an IP address from the local DHCP server.
  • B
    Bob WaltersAug 4, 2025
    How to force default static IP on Kantech IP Access Controllers?
    • J
      John SimsAug 4, 2025
      When JP2 is ON and JP3 is OFF, the Kantech IP Access Controller will perform the same actions as a 'Soft Reset,' but the IP address is forced to the default static IP: 192.168.1.2.
  • S
    stephaniebrownAug 14, 2025
    What happens during a hard reset of Kantech IP Access Controllers?
    • L
      Leah AnthonyAug 14, 2025
      When JP2 is OFF and JP3 is ON, a hard reset of the Kantech IP Access Controller will occur, which means that all of the controller's memory is set to default values, the internal event buffer is cleared, and the IP address is kept if valid. The controller generates the message 'Controller Hard Reset,' and the internal RTC (Real Time Clock) and clock are set to the default time and date values of January 1st 2005, 00:00:00, Saturday.

Summary

Pre-Installation Information

Copyright and Trademarks

Details copyright, trademarks, and product disclaimers.

Safety Instructions

Crucial safety guidelines for installing and operating the KT-400 controller.

Technical Support

Compliance Specifications

FCC & IC Compliance

Details compliance with FCC and Industry Canada regulations for digital apparatus.

UL Compliance Requirements

Lists requirements for UL listing, including specific component usage.

UL 294 and UL 1076 Notices

Specifies supplementary use for UL 294 access control and UL 1076 proprietary units.

KT-400 Overview

EntraPass Compatibility

Lists EntraPass editions compatible with the KT-400 controller.

Configuration Options

Explains methods for configuring the KT-400 controller (EntraPass, Web, KT-Finder).

Onboard Doors and Ports

Details the controller's four onboard doors and communication ports.

Controller Inputs and Outputs

Details the 16 onboard inputs, lock outputs, and relay outputs.

Reader Interfaces and System Connectivity

Describes reader interfaces, elevator, alarm, and port detection capabilities.

Firmware, Diagnostics, and Expansion

Covers firmware, troubleshooting, LEDs, and SPI expansion modules.

System Architecture

Network Integration Diagrams

Illustrates KT-400 integration via LAN, WAN, RS-485, and RS-232.

VITAL LED Heartbeat Patterns

Technical Specifications

Hardware and Environmental Specs

Details power, dimensions, weight, PCB size, reader types, and wiring.

Output and Communication Specs

Lists reader power, outputs, communication ports, speed, and memory.

Certifications and Listings

Encompasses FCC, EN, and UL certifications for the controller.

Electrical Specifications

Open Collector Outputs

Details current ratings for LEDs and buzzers.

Power Outputs and Ratings

Lists current ratings for auxiliary power, readers, locks, and relays.

Models, Documentation, and Items

KT-400 Controller Models

Lists available KT-400 controller and cabinet models.

Expansion Modules Models

Describes available expansion modules like input, relay, and output modules.

Related Documentation and Items

Lists reference manuals, cables, and accessories.

Installing the KT-400 Controller

Preparation, Grounding, and Location

Covers pre-installation checks, ideal location, and earth grounding.

Door Locking and Input Connections

Guides on connecting door lock devices and inputs.

Reader, Output, and Tamper Connections

Details connecting readers, keypads, outputs, and tamper switch.

Network and Power Connections

Covers connecting to RS-485, LAN, RS-232, and powering the unit.

SPI Expansion Module Installation

Details connecting expansion modules via SPI and current draw calculations.

Expansion Module Installation Rules

Provides important rules for installing expansion modules and cable lengths.

Troubleshooting and Resets

Reset Types and Patterns

Explains Soft, Hard, Forced Static, and Factory Default DHCP reset types.

Default Initialization

Factory Default DHCP Reset Procedure

Outlines the steps to perform a factory default DHCP reset.

Maintenance Recommendations

Battery Testing and Care

Details bi-annual battery tests and annual lithium-ion battery checks.

Web Configuration

Pre-Configuration Steps

Covers network information sheet completion and forced default static mode.

Web Configuration Process

Guides on accessing the web interface and saving configuration settings.

KT-Finder Configuration

KT-Finder Application Overview

Introduces the KT-Finder application for configuring the KT-400.

KT-Finder Configuration Steps

Details selecting the device, entering MAC address, and connecting.

Network Configuration Sheets

LAN Configuration Information

Provides a sheet for configuring the KT-400 within a Local Area Network.

WAN Configuration Information

Provides a sheet for configuring the KT-400 within a Wide Area Network.

Installation Checklist

Inputs and Outputs Assignments

Kantech Ethernet Four-Door Controller KT-400 Specifications

General IconGeneral
Number of Doors4
Event Buffer50, 000
HousingMetal
CommunicationEthernet
Power Supply12 VDC
Inputs8
Outputs8
CompatibilityEntraPass