SHUTTING DOWN & CLEAN-UP
SHUTTING DOWN
Step 1
Remove detergent suction tube from
container and insert into 1 gallon of fresh
water. Siphon water at low pressure for one
minute.
Step 2
Turn off the engine.
Step 3
Turn off the water source.
Step 4
Press trigger to release water pressure.
Step 5
Disconnect the garden hose from the water
inlet on the unit.
Step 6
Disconnect the high pressure hose from the
high pressure outlet and engage the gun
safety lock.
TAKING A BREAK
... five minutes or more
Step 1
Turn off the engine.
Step 2
Engage gun safety lock.
MAINTENANCE INSTRUCTIONS
Cleaning the water inlet filter
Pull out the water inlet filter with flat-nose
pliers and rinse filter in warm water.
Cleaning the detergent filter
Pull out the detergent suction tube and
rinse filter in warm water.
WINTERIZING AND
LONG-TERM STORAGE
1.Disconnect all water connections.
2.Turn on the machine for a few seconds,
until the water which had remained in
the pump exits. Turn off immediately.
3.Do not allow high pressure hose to
become kinked.
4.Store the machine and accessories in
a room which does not reach freezing
temperatures.
Caution: Failure to follow the above
directions will result in damage to the
pump assembly and accessories.
Kärcher also recommends the regular
practice of using a pump protector like
Kärcher Pump Protector to help during
storage in the winter months.