KC-S10Technical data
V
24
© KEBA 2022
12 Technical data
12.1 General
Protection class: II
Type of protection: IP65
Degree of soiling: 3
Overvoltage category: III
Impact resistance: IK08
Rated insulation voltage:
400 V (effective value in accordance with
EN61439-1)
Rated frequency (f
n
): 50 Hz
Flammability class: V2 (according to UL94)
Glow wire resistance: 960 °C (according to EN 60695-2-11)
12.2 Power supply
Nominal supply voltage (Europe): 3 x 230 V / 400 V
Nominal current:
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase or 3-phase
Power-line frequency: 50 Hz
Network configurations: TT / TN / IT
Internal consumption: 6.08 W
12.3 Interfaces
Terminals X2.1 / X2.2
Terminal: Floating contact
12.4 Ambient conditions
Use: Inside and outside area
Access limitations at set-up location: Limited and unlimited access
Installation (stationary): On a wall
Ambient temperature: -5 °C to 50 °C
Ambient temperature 24h: 35 °C
Storage temperature: -30 °C to +80 °C
Max. relative humidity:
● At 25 °C: 95% non-condensing
● At 40 °C: 50% non-condensing