CALIBRATING YOUR KEISER M SERIES EQUIPMENT
Procedure for software version U406 and above
STEP 4
STEP 5
STEP 6
555512_D
The magnets must align with the
tool as shown in the detail view
Pull the calibration tool
upward to the magnet
housing.
Turn the magnet housing
counter/anti-clockwise and
allow the magnets to rotate
into your calibration tool.
Release the magnet housing.
It will automatically make a
slight clockwise turn back
into its resting position.