REMOTE CONTROL
85
Standard Event Status Register Group
Overview
The Standard Event Status Register Group
indicates if any errors have occurred. The bits
of the Event register are set by the error event
queue.
Bit Summary
Event Bit #
Bit
Weight
OPC (Operation complete)
The OCP bit is set when all
selected pending operations are
complete. This bit is set in
response to the *OPC command.
0 1
RQC (Request control)
1 2
QUE (Query Error)
The Query Error bit is set in
response to an error reading the
Output Queue. This can be
caused by trying to read the
Output Queue when there is no
data present.
2 4
DDE (Device Dependent Error)
Device specific error.
3 8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2260B Series and is the answer not in the manual?

Keithley 2260B Series Specifications

General IconGeneral
Current Resolution0.1mA
Programming Accuracy (Current)0.1% + 5mA
Readback Accuracy (Current)0.1% + 5mA
Operating Temperature Range0°C to 50°C
Storage Temperature Range-40°C to 70°C
Voltage Resolution1mV
Remote InterfaceUSB, LAN, GPIB
Programming Accuracy (Voltage)0.03% + 5 mV
Protection FeaturesOvervoltage protection (OVP), Overcurrent protection (OCP), Overtemperature protection (OTP)
DisplayColor LCD
Dimensions88 mm x 214 mm x 374 mm

Related product manuals