Page #103 background image
2260B Series Programming Manual
100
Error Messages & Messages
The following error messages or messages may appear on the
2260B screen during operation.
Error Messages Description
Err 001 USB Mass Storage is not present
Err 002 No (such)file in USB mass storage
Err 003 Empty memory location
Messages Description
MSG 001 External control of output. Output off (F-94=0,
High=on)
MSG 002 External control of output. Output off (F-94=1,
Low=on)
MSG 003 F-93 is not zero. Unable to calibrate.
LED Display Format
Use the following table to read the LED display messages.
0 1 2 3
4
5
6
7
8 9
A
B
C
D
E F G H
I J K
L
M N
O
P
Q
R
S T U V
W
X
Y
Z
( ) +
- ,

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2260B Series and is the answer not in the manual?

Keithley 2260B Series Specifications

General IconGeneral
Current Resolution0.1mA
Programming Accuracy (Current)0.1% + 5mA
Readback Accuracy (Current)0.1% + 5mA
Operating Temperature Range0°C to 50°C
Storage Temperature Range-40°C to 70°C
Voltage Resolution1mV
Remote InterfaceUSB, LAN, GPIB
Programming Accuracy (Voltage)0.03% + 5 mV
Protection FeaturesOvervoltage protection (OVP), Overcurrent protection (OCP), Overtemperature protection (OTP)
DisplayColor LCD
Dimensions88 mm x 214 mm x 374 mm