SCPI Tables 12-13
:SENSe2
:AVERage? Query average count.
:CURRent [:DC] Path to configure the current measurement function: ✓
:RANGe Current measurement range: ✓
[:UPPer] <NRf> Specify expected current measurement which will
se
lect 5mA or 5A for current range.
5.0 ✓
[:UPPer]? Query current measurement range. ✓
:AUTO <b> Enable or disable auto range. OFF ✓
:AUTO? Query state of auto range.
:PCURrent Path to configure the pulse-current measurement function
(refer
to Section 3):
:AVERage <NRf> Specify average count (dependent on SYNC:STAT):
pulse-current measurements: 1 to 100 (sync ON)
pulse current digitization: 1 to 5000 (sync OFF)
1
:AVERage? Query average count (dependent on SYNC:STAT).
:MODE <name> Select pulse-current measurement mode (HIGH, LOW,
or A
VERage).
HIGH
:MODE? Query pulse-current measurement mode.
:TIME Path to set pulse-current integration times:
:AUTO Power supply sets integration times — accounts for
internal trigger delay
but not user delay (:DEL).
:HIGH <NRf> Specify integration time (in sec) for high pulse
measurements
(33.33E-06 to 0.8333) — accounts
neither for internal trigger delay nor user delay.
3.333E-05
:HIGH? Query high integration time.
:LOW <NRf> Specify integration time (in sec) for low pulse
measurements
(33.33E-06 to 0.8333) — accounts
neither for internal trigger delay nor user delay.
3.333E-05
:LOW? Query low integration time.
:AVERage <NRf> Set integration time in seconds for measurement of
pulse A
VERage time — accounts neither for
internal trigger delay nor user delay.
3.333E-05
:AVERage? Query average integration time.
:DIGitize <NRf> Specify integration time (in sec) for digitizing or burst
measurements; 33.33e-6 to 0.8333.
3.333e-5
Table 12-4 (cont.)
SENSe command summary (refer to Tables 2-3, 3-2, and 4-2) (cont.)
Command Description
Default
parameter
SCPI
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

Table of Contents

Other manuals for Keithley 2306

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2306 and is the answer not in the manual?

Keithley 2306 Specifications

General IconGeneral
BrandKeithley
Model2306
CategoryPower Supply
LanguageEnglish

Related product manuals