EasyManuals Logo

Keithley SourceMeter 2400 Series User Manual

Keithley SourceMeter 2400 Series
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
5 Pulse Mode Operation (Model 2430 only)
Overview .................................................................................... 5-2
Pulse characteristics .................................................................... 5-3
Pulse width .......................................................................... 5-4
Signal measurement ..................................................... 5-4
Overhead time .............................................................. 5-4
Pulse width delay ......................................................... 5-5
Output off-time .................................................................... 5-5
Reference and zero measurements ............................... 5-5
Overhead time .............................................................. 5-5
Pulse delay ................................................................... 5-6
Pulse duty cycle ................................................................... 5-6
Fast pulse output .................................................................. 5-6
Auto zero ...................................................................... 5-7
Pulse-only ..................................................................... 5-8
Pulse jitter ............................................................................ 5-8
Pulse energy limitations (10A range) ......................................... 5-9
Pulse Mode configuration ......................................................... 5-10
Front panel Pulse Mode configuration .............................. 5-10
Select Pulse Mode, and set pulse width
and pulse delay ....................................................... 5-10
Set pulse measurement speed ..................................... 5-10
Set pulse count ........................................................... 5-10
Disable/enable auto zero ............................................ 5-11
Remote command Pulse Mode configuration ................... 5-11
Basic Pulse Mode operation ..................................................... 5-12
Front panel pulse-measure procedure ............................... 5-12
Step 1: Select Pulse Mode, and set pulse width
and pulse delay. ...................................................... 5-12
Step 2: Set pulse measurement speed. ....................... 5-12
Step 3: Set pulse count. .............................................. 5-12
Step 4: Select source. ................................................. 5-13
Step 5: Set pulse level and compliance limit. ............. 5-13
Step 6: Select measurement function and range. ....... 5-13
Step 7: Turn output on. ............................................... 5-14
Pulse-ohms measurements ................................................ 5-14
Auto and Manual pulse-ohms measurements ............ 5-14
Offset-compensated pulse-ohms measurements ........ 5-14
Remote command pulse-measure operation ..................... 5-15
Basic pulse commands ............................................... 5-15
Ignored settings and invalid commands ..................... 5-15
Pulse-measure programming example ....................... 5-16
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Keithley SourceMeter 2400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley SourceMeter 2400 Series and is the answer not in the manual?

Keithley SourceMeter 2400 Series Specifications

General IconGeneral
BrandKeithley
ModelSourceMeter 2400 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals