Do you have a question about the Keithley Interactive SourceMeter 2450 and is the answer not in the manual?
Model | 2450 |
---|---|
Type | SourceMeter |
Category | Measuring Instruments |
Maximum Voltage | 200 V |
Maximum Current | 1 A |
Maximum Power | 20 W |
Display | 5-inch capacitive touchscreen |
Touchscreen Display | Yes |
Connectivity | USB, LAN, GPIB |
Measurement Resolution | 6.5 digits |
Interface | USB, GPIB |
Functions | Sourcing and measuring voltage and current |
Details electrical safety requirements, including voltage hazards and protective measures.
Provides instructions for safe handling of power cords, cables, and connections.
Explains the meaning of various safety symbols used on the instrument.
Safety advice regarding maintenance, component replacement, and cleaning.
Provides a visual and textual description of the Model 2450's front panel controls.
Provides step-by-step instructions for connecting power and turning the instrument on/off.
Explains how to control the instrument's output from the front panel or remotely.
Provides steps to copy measurement data to a USB flash drive in CSV format.
Discusses selecting communication interfaces for sending commands and receiving responses.
Provides steps to set the GPIB address from the front panel.
Explains communicating with the instrument over a local area network.
Details setting up manual or automatic LAN communications on the instrument.
Provides common troubleshooting steps for LAN connectivity issues.
Step-by-step guide to performing a basic measurement from the front panel.
Step-by-step instructions to configure the instrument for low-resistance measurement.
Provides SCPI commands to perform 100 low-resistance measurements.
Provides TSP code to perform 100 low-resistance measurements.
Demonstrates measuring leakage current of a 1 nF capacitor over time.
Step-by-step guide to set up leakage current measurement from the front panel.
Provides SCPI commands for capacitor leakage measurement.
Provides TSP code for capacitor leakage measurement.
Introduces measuring insulator resistance using the Model 2450.
Step-by-step guide to set up insulation resistance measurement from the front panel.
Provides SCPI commands for insulation resistance measurement.
Provides TSP code for insulation resistance measurement.
Provides SCPI commands for FET testing using a trigger model.
Provides SCPI commands for FET testing using a linear sweep.
Provides TSP commands for FET testing using a trigger model.
Provides TSP commands for FET testing using a linear sweep.
Explains automating battery charge/discharge tests using SCPI or TSP commands.
Provides SCPI commands for battery application testing.
Provides TSP code for battery application testing.
Outlines steps for characterizing a solar cell using the Model 2450.
Step-by-step guide to set up solar cell I-V sweep from the front panel.
Provides SCPI commands for solar cell I-V sweep.
Provides TSP commands for solar cell I-V sweep.