Do you have a question about the Keithley SourceMeter 2400 and is the answer not in the manual?
Model | 2400 |
---|---|
Type | SourceMeter |
Power Range | 20 W |
Measurement Speed | up to 1000 readings/second |
Maximum Voltage | 200 V |
Maximum Current | 1 A |
Power | 20 W |
Interface | GPIB, RS-232, USB, Ethernet |
Max Power | 20 W |
Display | LCD |
Display Digits | 5-1/2 |
Details controls, connectors, and indicators on the front and rear panels.
Explains 2-wire local and 4-wire remote sensing for basic operations.
Covers capabilities, compliance limits, and fundamental source-measure configuration.
Provides a step-by-step guide for setting up source-measure operations.
Discusses auto and manual measurement methods and how to select them.
Describes timing characteristics like pulse width and output off-time.
Explains how to select and configure pulse width, delay, speed, and count.
Provides front panel procedures and commands for pulse-measure operations.
Discusses compliance limits, types, and how they determine operating boundaries.
Information on preventing overheating, including power equations to avoid shutdown.
Covers voltage and current limits for source and sink operations across models.
Covers maximum readings, ranging limitations, manual/auto ranging, and display resolution.
Discusses speed settings to control A/D converter integration time for accuracy and noise.
Details built-in math functions like Power, Offset-Compensated Ohms, and others.
Provides the procedure for saving readings into the internal buffer.
Describes linear staircase, logarithmic staircase, custom, and source memory sweep types.
Details the procedure for setting up and performing sweeps, including delay and range.
Discusses front panel triggering, trigger model, event detection, and configuration.
Details the actions within the SDM cycle.
Shows how to program the instrument for front panel trigger operation.
Discusses compliance, coarse, and fine limits, and grading/sorting modes.
Discusses input/output lines and the +5V output for external logic circuits.
Details configuration of the Digital I/O Port for interlock and output off states.
Describes HIGH IMPEDANCE, NORMAL, ZERO, and GUARD output-off states.
Summarizes remote operation enhancements and local/remote transitions.
Details programming the Status Byte to generate SRQs and using serial polling.
Provides detailed information on commands to set up measurement functions.
Describes commands to acquire post-processed, triggered, or single measurements.
Details commands for configuring and controlling I-Source, V-Source, and digital output lines.
Provides detailed electrical and physical specifications for SourceMeter models.
Explains how the Status Byte Register and SRQ are controlled.
Triggers and acquires readings, returning data after operations complete.
Describes how to configure the SourceMeter for limit testing and provides a typical test procedure.