Kelly KLS-M/N Brushless Motor Controller Users Manual V 2.5
23
(3)Speed Sensor Type: Speed Sensor Type, 2:Hal, 3:Resolver, 4:Line Hall. Range: 2~4
Different sensors type.By defualt,it is set at 2
If you have a motor with 5V,Sin/Cosin,GND speed sensors,please choose it at 4.And please
inquire the KLS-8080IPS model before ordering.
(4)Resolver Poles: Resolver Poles, The pair pole number*2. Range: 2~32
It is only used for the Resolver sensor type.
(5)Motor Temp Sensor: Motor Temp Sensor, 0
None,1:KTY84-130 or 150,2:KTY83-122.Range
0-2
High Temp Cut Out
°
C: Motor High Temp Cut Out, nominal value 130
°
C. Range: 60~170
Resume
°
C: Motor High Temp Resume Temp, nominal value 110
°
C.The controller will
resume work when the motor temp is at 110 degrees inside. Range: 60~170
(6)Line Hall Zero:It is only useful when the speed sensor is at 4.
Useless for KLS-N or KLS-M model.
4.3 Step 3
(1)RLS_TPS Brk %: RLS TPS Braking Percent, the percent of Releasing Pedal BRK in max
braking. Range: 0~50
This is used to adjust the regen current of releasing throttle regen mode type.The regen will
happen as long as the throttle is released completely.
Factory set is 0
(2)NTL Brk %: NTL Braking Percent, the percent of Neutral Braking in max braking. Range:
0~50
Only useful when you enable Three gears switch in user program.
The regen will happen when you turn F-N-R switch from Forward or backward to Neutral
position.
Factory set is 0
(3)Accel Time: Accel Time, the time of TPS Torque from 0 to max, accuracy 0.1s, 5 is equal to
0.5s. Range: 1~250
Factory set is 10
(4)Accel Rls Time: Accel Release Time, the time of TPS Torque from max to 0, accuracy 0.1s.
Range: 1~250
Factory set is 1
(5)Brake Time: Brake Time, the time of Brake Torque from 0 to max, accuracy 0.1s. Range:
1~250
Factory set is 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kelly KLS Series and is the answer not in the manual?

Kelly KLS Series Specifications

General IconGeneral
Motor TypeBLDC, PMSM
DimensionsVaries by model
WeightVaries by model
Voltage Range24V-72V
Storage Temperature Range-40°C to 85°C
CommunicationCAN
Protection FeaturesOver-voltage, Under-voltage, Over-current, Over-temperature, Short-circuit
Operating Frequency16kHz