Kelly KLS-M/N Brushless Motor Controller Users Manual V 2.5
31
2,2 ¤¤ ¤¤
Internal volts fault
1. Measure that B+ & PWR are correct when
measured to B- or RTN.
2. There may be excessive load on the +5V supply
caused by too low a value of Regen or throttle
potentiometers or incorrect wiring.
3. Controller is damaged. Contact Kelly about a
warranty repair.
4. If this error code occurs,the relay function on plin9
will be deactivated.
2,3 ¤¤ ¤¤¤
Over temperature
The controller temperature has exceeded 100. The
controller will be stopped but will restart when
temperature falls below 80.
2,4 ¤¤ ¤¤¤¤
Throttle error at
power-up
Throttle signal is higher than the preset ‘dead zone’ at
Power On. Fault clears when throttle is released.
3,1 ¤¤¤ ¤
Reserved
3,2 ¤¤¤ ¤¤
Internal reset
May be caused by some transient fault condition like
a temporary over-current, momentarily high or low
battery voltage. This can happen during normal
operation.
3,3 ¤¤¤ ¤¤¤
Hall throttle is open
or short-circuit
When the throttle is repaired, a restart will clear the
fault.
3,4 ¤¤¤ ¤¤¤¤
Angle sensor error
1.Speed sensor type errorcustomers may set the
correct sensor type through user program or App.
Please download how to use Identification function
instruction from our website.
2.Incorrect wiring.
3.Speed sensor is damaged or defective.Or feedback
signal is erratic.
4,1 ¤¤¤¤ ¤
Reserved
4, 2 ¤¤¤¤ ¤¤
Reserved
4, 3 ¤¤¤¤ ¤¤¤
Motor
over-temperature
Motor temperature has exceeded the configured
maximum. The controller will shut down until the
motor temperature cools down.
4, 4 ¤¤¤¤ ¤¤¤¤
Hall Galvanometer
sensor error
1.Hall galvanometer device is damaged inside the
controller.
This error code is only valid for KLS-8080I controller.
Customers may read error codes in PC software or Android Tablet

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kelly KLS Series and is the answer not in the manual?

Kelly KLS Series Specifications

General IconGeneral
Motor TypeBLDC, PMSM
DimensionsVaries by model
WeightVaries by model
Voltage Range24V-72V
Storage Temperature Range-40°C to 85°C
CommunicationCAN
Protection FeaturesOver-voltage, Under-voltage, Over-current, Over-temperature, Short-circuit
Operating Frequency16kHz