7.3 Troubleshooting
Not all dust
particles are
collected
Distance between the
extraction hood and the
welding position too great
Move the extraction hood
closer
Clean air outlet obstructed
Keep clean air outlet free of
obstruction
The set minimum
extraction capacity has not
been reached. Filter inserts
saturated,
piping/extraction system
closed off
Filter change required,
check piping/extraction
system, contact service
Requirements are no
longer met!
Extraction
capacity too
low/non-
existent
Dust particles
escape on the
clean air side
Have this checked by a
qualified electrician
Automatic
Start/Stop does
not function
Plug in the extraction arm
is bridged
Remove the extraction arm
from the product and
remove the plug bridge
Product will not
start up
Have this checked by a
qualified electrician
If the fault cannot be corrected by the customer, please contact the
manufacturer’s service department.