3. DC-LINK CAPACITOR CARD Z002
3.1. Capacitors (C1-C8) and discharge resistors (R1-R4)
The purpose of the DC-link capacitors (C1-C8) is to provide energy storage and low impedance voltage source for the
power stage. Resistors (R1-R4) discharge DC-link capacitors when power source is switched off.
3.2. Connectors
Connector Description
X1 DC-link voltage (+)
X2 DC-link voltage (+)
X3 DC-link voltage (-)
X4 DC-link voltage (-)