SERVICE MANUAL
FASTMIG X
10 (37)
Kemppi OY
5. SECONDARY CUT OFF CARD Z004
Secondary cut-off card Z004 is used to make special welding characteristics. There is a need of a very quick current
cut-off in a certain stage in PipeRoot welding process
Mosfets V6-V45 are controlled to non-conductive state while the certain very short time period
In order to control those mosfets they need isolated voltage from secondary shunt-, because mosfets sources are
connected to main choke+. The isolated voltage +15Vdc in C7 is generated from +24Vdc by using forward converter
with V1 and T1. Control gate signal is generated in the processor card A002 isolated from the mosfet gates through an
optical driver H1
A resistor R004 is used to reduce voltage spikes while those PipeRoot periods
The whole secondary current goes through secondary profile between rectifier card Z003 and cut-off card Z004
5.1. Connectors
Connector Description
X1:1 Optical coupler anode
X1:2 Optical coupler cathode
X1:3 Not in use
X1:4 +24Vdc
X1:5 FET FAILURE signal
X1:6 GND
X5-X8 Secondary choke

Table of Contents

Other manuals for Kemppi FastMig MXF 37 Pipe

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig MXF 37 Pipe and is the answer not in the manual?

Kemppi FastMig MXF 37 Pipe Specifications

General IconGeneral
BrandKemppi
ModelFastMig MXF 37 Pipe
CategoryWelding System
LanguageEnglish

Related product manuals