9. TECHNICAL DATA
FastMig KMS 300 FastMig KMS 400 FastMig KMS 500
Connection voltage
3~, 50/60 Hz
400 V -15 %...+20 % 400 V -15 %...+20 % 400 V -15 %...+20 %
Rated power
60 ED
- - 26.1 kVA
80 % ED
- 19.5 kVA -
100 % ED
13.9 kVA 18.5 kVA 20.3 kVA
Connection cable
H07RN-F 4G6 (5 m) H07RN-F 4G6 (5 m) H07RN-F 4G6 (5 m)
Fuse (delayed)
25 A 35 A 35 A
Output 40 °C
60 % ED
- - 500 A
80 % ED
- 400 A -
100 % ED
300 A 380 A 430 A
Welding current and voltage range
MMA
10 A – 300 A 10 A – 400 A 10 A – 500 A
MIG
10 V 37 V 10 V 39 V 10 V – 42 V
Max. welding voltage
46 V 46 V 46 V
Open circuit voltage
50 V 50 V 50 V
Idle power
25 W 25 W 25 W
Efficiency at max. current
87 % 87 % 87 %
Power factor at max. current
0.9 0.9 0.9
Operating temperature range
-20 ... +40 °C -20 ... +40 °C -20 ... +40 °C
Storage temperature range
-40 ... +60 °C -40 ... +60 °C -40 ... +60 °C
Degree of protection
IP23S IP23S IP23S
EMC class
A A A
Minimun short circuit power S
sc
of supply network*
- 4.7 MVA 4.6 MVA
External dimensions
length
590 mm 590 mm 590 mm
width
230 mm 230 mm 230 mm
height
430 mm 430 mm 430 mm
weight
34 kg 35 kg 36 kg
Voltage supply for auxiliary
devices
50 V DC 50 V DC 50 V DC
X14, X15
fuse 6.3 A delayed fuse 6.3 A delayed fuse 6.3 A delayed
Operating voltage
(for cooling unit)
400 V -15 %...+20 % 400 V -15 %...+20 % 400 V -15 %...+20 %
* See paragraph 2.2.
11
FastMig KMS 300, 400, 500 / © Kemppi Oy / 1110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi Kms 400 and is the answer not in the manual?

Kemppi Kms 400 Specifications

General IconGeneral
BrandKemppi
ModelKms 400
CategoryWelding System
LanguageEnglish

Related product manuals