Control card A001
Error codes
Error 8:
• PMT torch has overheated. This function can be disabled by removing jumper
5 when using standard MIG guns (without RMT-10 and overheat protection
facilities).
Error 9:
• Overload of wire feed motor.
Error 10:
• Power source does not start, when start message is sent. This error can be
caused by following reasons (for example):
– Power source overheated
– Power source faulty
– Two wire feeders with same address (jumpers 1 & 2) has been connected
to the Probus.
Error 11:
• Jumper 5 (which prevents PMT-torches RMT-10 and overheat protection
facilities) has been removed from control card and and PMT torch has been
connected to wire feed unit.
Error 12:
• The link between X3,4 and X3,6 is open.