ELECTRICAL REQUIREMENTS
■ A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker on a
separate circuit serving only this washer is recommended.
■ This washer is equipped with a power supply cord having a
3-prong grounding plug.
■ To minimize possible shock hazard, the cord must be plugged
into a mating, 3-prong, grounding-type outlet, grounded in
accordance with local codes and ordinances. If a mating outlet
is not available, it is the personal responsibility and obligation
of the customer to have the properly grounded outlet installed
by a qualied electrician.
■ If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the
ground path is adequate.
■ Do not ground to a gas pipe.
■ Check with a qualied electrician if you are not sure the
washer is properly grounded.
■ Do not have a fuse in the neutral or ground circuit.