Water Filter Data
System Specification and Performance Data Sheet
® Refrigerator Water Filter Cartridge Model 9005
Specifications
Service Flow Rate (Maximum) ............................................. 075 GPM (283 L/min)
Rated Service Life Model 9005 (Maximum) ......................... 500 gallons/ 1892 liters
Maximum Operating Temperature ........................................ 100 ° F/38 ° C
Minimum Pressure Requirement .......................................... 35 psi/ 138 kPa
Maximum Operating Pressure .............................................. 120 psi/827 kPa
]
General Use Conditions: Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs.
DO NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system. System certified for cyst reduction may be used on disinfected water that may contain
filterable cysts.
The retractable water filtration system uses a 9005 replacement cartridge (see Sears contact information at the front of your
manual to order). Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system.
Please refer to the applicable section in this Use and Care Guide for general operation, maintenance requirements and
troubleshooting.
This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in
ANSl/NSF 42 and 53.
Performance Data*
Substance
Lead
Lead
Cyst
Turbidity
Lindane
Atrazine
Chlorine
Particulate**
2,4-D
Asbestos
Influent
Water
0.15 mg/L
O.15 mg/L
25000 count/mL
11.8 NTU
0.00063 mg/L
0.0097 mg/L
1,9 mg/L
286667 count/mL
291.6667 ug/L
458 MFL/mL
Effluent
Average
0.001 mg/L
0.002 mg/L
lcount/mL
0,12 NTU
0.00005 mg/L
0.0002 mg/L
0,09 mg/L
900 count/mL
45.45 ug/L
0,16 MFL/mL
Average
%
Reduction
99.33%
96.66%
99.99%
98,98%
92.06%
97.93%
95.26%
99.68%
84.42%
99.96%
Maximum
Effluent
0.001 mg/L
0.003 mg/L
3 count/mL
0,18 NTU
0.00005 mg/L
0.0006 mg/L
0,17 mg/L
2400 count/mL
1OOug/L
0,16 MFL/mL
Min. Required Inlet
Reduction pH
0.010 mg/L 6,5
0.010 mg/L 8.5
> 99.95% NA
0.5 NTU NA
0.00001 mg/L NA
0.003 mg/L NA
->75% NA
->85% NA
0.0017 mg/L NA
99% NA
." Tested using a flow rate of 0.75 GPM (2.83 L/min,) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions; however, actual performance may vary. Health Claim
Performance tested and certified by NSF International.
Particle size range classification of test. Particles used were 0.5 -1 microns.