- 5 -
HIGH SIDE LOW SIDE
70°F 98 (+10 / -10) 98 (+5 / -3) (-5) to (-2)
90°F 98 (+10 / -10) 130 (+3 / -3) (-4) to 1
110°F 103 (+5 / -5) 174 (+5 / -5) (-2) to 3
AMB WATTS
SYSTEM PRESSURE (PSIG)
PERFORMANCE DATA
(NORMAL OPERATING CONDITIONS)
1-7. REPLACEMENT PARTS
Relay...........................................................
Overload.....................................................
Defrost Thermostat.....................................
Defrost Heater............................................
Evaporator Fan Motor.................................
Capacitor CR..............................................
Capacitor CS..............................................
Compressor (Hi-Side).................................
Evaporator (Lo-Side)..................................
Condenser..................................................
Dryer............................................................
Condenser Fan Motor.................................
Temperature Control...................................
Main Control................................................
1-8. AIR FLOW
EBG42993602
EAF39584205
6615JB2002R
5300JB1102D
5901JA1022A
0CZZJB2010H
J513-00012P
TCA31748011
ADL72916201
5403JA1003A
5851JA2007A
5901JJ1019A
EBR61526804
EBR61526803
EBR64585301
EVAPORATOR
EVAPORATOR FAN
DRYER
HOT LOOP
COMPRESSOR
CONDENSER
CONDENSER
FAN
COLD AIR
MIXED AIR
AIR RETURN TO
EVAPORATOR